239 research outputs found

    Lorenz gauged vector potential formulations for the time-harmonic eddy-current problem with L∞-regularity of material properties

    Get PDF
    In this paper we consider some Lorenz gauged vector potential formulations of the eddy-current problem for the time-harmonic Maxwell equations with material properties having only L1-regularity. We prove that there exists a unique solution of these problems, and we show the convergence of a suitable finite element approximation scheme. Moreover, we show that some previously proposed Lorenz gauged formulations are indeed formulations in terms of the modified magnetic vector potential, for which the electric scalar potential is vanishing

    Sensors for Rate Responsive Pacing

    Get PDF
    Advances in pacemaker technology in the 1980s have generated a wide variety of complex multiprogrammable pacemakers and pacing modes. The aim of the present review is to address the different rate responsive pacing modalities presently available in respect to physiological situations and pathological conditions. Rate adaptive pacing has been shown to improve exercise capacity in patients with chronotropic incompetence. A number of activity and metabolic sensors have been proposed and used for rate control. However, all sensors used to optimize pacing rate metabolic demands show typical limitations. To overcome these weaknesses the use of two sensors has been proposed. Indeed an unspecific but fast reacting sensor is combined with a more specific but slower metabolic one. Clinical studies have demonstrated that this methodology is suitable to reproduce normal sinus behavior during different types and loads of exercise. Sensor combinations require adequate sensor blending and cross checking possibly controlled by automatic algorithms for sensors optimization and simplicity of programming. Assessment and possibly deactivation of some automatic functions should be also possible to maximize benefits from the dual sensor system in particular conditions. This is of special relevance in patient whose myocardial contractility is limited such as in subjects with implantable defibrillators and biventricular pacemakers. The concept of closed loop pacing, implementing a negative feedback relating pacing rate and the control signal, will provide new opportunities to optimize dual-sensors system and deserves further investigation. The integration of rate adaptive pacing into defibrillators is the natural consequence of technical evolution

    Early Outcomes of Out-of-Hospital Cardiac Arrest after Early Defibrillation: a 24 Months Retrospective Analysis

    Get PDF
    Introduction: Cardiovascular disease remains the most common cause of death in the United States and most other Western nations. Among these deaths, sudden, out-of-hospital cardiac arrest claims approximately 1000 lives each day in the United States alone. Most of these cardiac arrests are due to ventricular fibrillation. Though highly reversible with the rapid application of a defibrillator, ventricular fibrillation is otherwise fatal within minutes, even when cardiopulmonary resuscitation is provided immediately. The overall survival rate in the United States is estimated to be less than 5 percent. Recent developments in automated-external-defibrillator technology have provided a means of increasing the rate of prompt defibrillation after out-of-hospital cardiac arrest. After minimal training, nonmedical personnel (e.g., flight attendants and casino workers) are also able to use defibrillators in the workplace, with lifesaving effects. Nonetheless, such programs have involved designated personnel whose job description includes assisting persons who have had sudden cardiac arrest. Data are still lacking on the success of programs in which automated external defibrillators have been installed in public places to be used by persons who have no specific training or duty to act. Materials and Methods: All patients who had an out-of-hospital cardiac arrest between January 2003 and December 2004 and who received early defibrillation for ventricular fibrillation were included. We conducted a 24 months retrospective population-based analysis of the outcome in our population. Results: Over a 24 month period, 446 people had non–traumatic cardiac arrest, and in all of them it was observed to be ventricular fibrillation. In a very few cases, the defibrillator operators were good Samaritans, acting voluntarily. Eighty-nine patients (about 19%) with ventricular fibrillation were successfully resuscitated, including eighteen who regained consciousness before hospital admission. Conclusion: Automated external defibrillators deployed in readily accessible, well-marked areas, are really very effective in assisting patients with cardiac arrest. However, it's quite true that, in the cases of survivors, most of our users had good prior training in the use of these devices

    Pacemaker Prevention Therapy in Drug–refractory Paroxysmal Atrial Fibrillation: Reliability of Diagnostics and Effectiveness of Prevention Pacing Therapy in Vitatronℱ Selection¼ device

    Get PDF
    Introduction. Atrial fibrillation (AF), the most common and rising disorder of cardiac rhythm, is quite difficult to control and/or to treat. Non pharmacological therapies for AF may involve the use of dedicated pacing algorithms to detect and prevent atrial arrhythmia that could be a trigger for AF onset. Selection 900E/AF2.0 Vitatron DDDRP pacemaker (1) keeps an atrial arrhythmia diary thus providing detailed onset reports of arrhythmias of interest, (2) provides us data about the number of premature atrial contractions (PACs) and (3) plots heart rate in the 5 minutes preceding the detection of an atrial arrhythmia. Moreover, this device applies four dedicated pacing therapies to reduce the incidence of atrial arrhythmia and AF events. Aim of the Study. To analyze the reliability to record atrial arrhythmias and evaluate effectiveness of its AF preventive pacing therapies. Material and Methods. We enrolled 15 patients (9 males and 6 females, mean age of 71±5 years, NYHA class I–II), with a DDDRP pacemaker implanted for a “bradycardia–tachycardia” syndrome, with advanced atrioventricular conduction disturbances. We compared the number and duration of AF episodes’ stored in the device with a contemporaneous 24h Holter monitoring. After that, we switched on the atrial arrhythmias detecting algorithms, starting from an atrial rate over 180 beats per minute for at least 6 ventricular cycles, and ending with at least 10 ventricular cycles in sinus rhythm. Thereafter, in order to evaluate the possible reduction in PACs number and in number and duration of AF episodes, we tailored all the four pacing preventive algorithms. Patients were followed for 24±8 months (from 20 to 32 months). Results. All 59 atrial arrhythmia episodes occurred in the first part of this trial, were correctly recorded by both systems, with a correlation coefficient (r) of 0.96. During the follow–up, we observed a significant reduction not only in PACs number (from 83±12/day to 2.3±0.8/day) but also in AF episodes (from 46±7/day to 0.12±0.03/day) and AF burden (from 93%±6% to 0.3%±0.06%). An increase in atrial pacing percentages (from 3%±0.5% to 97%±3%) was also contemporaneously observed. Conclusion. In this pacemaker, detection of atrial arrhythmia episodes is highly reliable, thus making available an appropriate monitoring of heart rhythm, mainly suitable in AF asymptomatic patients. Moreover, the significant reduction of atrial arrhythmia episodes indicates that this might represent a suitable therapeutic option for an effective preventive therapy of AF in paced brady–tachy patients

    Atrial Fibrillation and Pacing Algorithms

    Get PDF
    Pacing prevention algorithms have been introduced in order to maximize the benefits of atrial pacing in atrial fibrillation prevention. It has been demonstrated that algorithms actually keep overdrive atrial pacing, reduce atrial premature contractions, and prevent short-long atrial cycle phenomenon, with good patient tolerance. However, clinical studies showed inconsistent benefits on clinical endpoints such as atrial fibrillation burden. Factors which may be responsible for neutral results include an already high atrial pacing percentage in conventional DDDR, non-optimal atrial pacing site and deleterious effects of high percentages of apical ventricular pacing. Atrial antitachycardia pacing (ATP) therapies are effective in treating spontaneous atrial tachyarrhythmias, mainly when delivered early after arrhythmia onset and/or on slower tachycardias. Effective ATP therapies may reduce atrial fibrillation burden, but conflicting evidence does exist as regards this issue, probably because current clinical studies may be underpowered to detect such an efficacy. Wide application of atrial ATP may reduce the need for hospitalizations and electrical cardioversions and favorably impact on quality of life. Consistent monitoring of atrial and ventricular rhythm as well as that of ATP effectiveness may be extremely useful for optimizing device programming and pharmacological therapy

    Endolymphatic potassium of the chicken vestibule during embryonic development

    Get PDF
    The endolymph fills the lumen of the inner ear membranous labyrinth. Its ionic composition is unique in vertebrates as an extracellular fluid for its high-K(+)/low-Na(+) concentration. The endolymph is actively secreted by specialized cells located in the vestibular and cochlear epithelia. We have investigated the early phases of endolymph secretion by measuring the endolymphatic K(+) concentration in the chicken vestibular system during pre-hatching development. Measurements were done by inserting K(+)-selective microelectrodes in chicken embryo ampullae dissected at different developmental stages from embryonic day 9 up to embryonic day 21 (day of hatching). We found that the K(+) concentration is low (<10mM/L) up to embryonic day 11, afterward it increases steeply to reach a plateau level of about 140 mM/L at embryonic day 19--21. We have developed a short-term in vitro model of endolymph secretion by culturing vestibular ampullae dissected from embryonic day 11 chicken embryos for a few days. The preparation reproduced a double compartment system where the luminal K(+) concentration increased along with the days of culturing. This model could be important for (1) investigating the development of cellular mechanisms contributing to endolymph homeostasis and (2) testing compounds that influence those mechanisms

    Calyx and dimorphic neurons of mouse Scarpa's ganglion express histamine H3 receptors

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Histamine-related drugs are commonly used in the treatment of vertigo and related vestibular disorders. The site of action of these drugs however has not been elucidated yet. Recent works on amphibians showed that histamine H3 receptor antagonists, e.g. betahistine, inhibit the afferent discharge recorded from the vestibular nerve. To assess the expression of H3 histamine receptors in vestibular neurons, we performed mRNA RT-PCR and immunofluorescence experiments in mouse Scarpa's ganglia.</p> <p>Results</p> <p>RT-PCR analysis showed the presence of H3 receptor mRNA in mouse ganglia tissue. H3 protein expression was found in vestibular neurons characterized by large and roundish soma, which labeled for calretinin and calbindin.</p> <p>Conclusion</p> <p>The present results are consistent with calyx and dimorphic, but not bouton, afferent vestibular neurons expressing H3 receptors. This study provides a molecular substrate for the effects of histamine-related antivertigo drugs acting on (or binding to) H3 receptors, and suggest a potential target for the treatment of vestibular disorders of peripheral origin.</p
    • 

    corecore